surgical protocol

Implant system

ShapeOne

heights from 8 to 16 mm

Connectors, drills, countersinks and taps

Connectors: HDH25S and HDH25L

Ø
Final drills (Bone d4)
Final drills (Bone d3-d2-d1)
Countersinks (Bone d3-d2-d1)
Taps (Bone d1)
3.7
D2428M
D2833M
CSD37
TAPS1B37
4.1
D2833M
D3338M
CSD41
TAPS1B41
4.7
D3338M
D3844M
CSD47
TAPS1B47

Connectors: HDH25S and HDH25L

Ø
Final drills (bone d4)
Final drills (bone d3-d2-d1)
Countersinks (Bone d3-d2-d1)
Taps (bone d1)
3.7
D2428M
D2833M
CSD37
TAPS1B37
4.1
D2833M
D3338M
CSD41
TAPS1B41
4.7
D3338M
D3844M
CSD47
TAPS1B47

Abutment included in the packaging

Connectors: HDH25S and HDH25L

Ø
Final drills (bone d4)
final drills (bone d3-d2-d1)
Countersinks (bone d3-d2-d1)
taps (bone d1)
3.7
D2428M
D2833M
CSD37
TAPS1B37
4.1
D2833M
D3338M
CSD41
TAPS1B41
4.7
D3338M
D3844M
CSD47
TAPS1B47

After removing the abutment, close the implant

Connectors: HDH31S and HDH31L

Ø
Final drills (bone d4)
Final drills (bone d3-d2-d1)
Countersinks (bone d3-d2-d1)
taps (bone d1)
3.7
D2428M
D2833M
CSD37
TAPS1B37
4.1
D2833M
D3338M
CSD41
TAPS1B41
4.7
D3338M
D3844M
CSD47
TAPS1B47

Different phases of the insertion

Sink countersink: up to 1.4mm for d3 medium bone/ up to 2.8mm for d2 medium bone and d1 compact bone
Use 3.7 countersink and 3.7 tap
For S1T implant system use the removal tool for abutments TRT after the implant has been placed in the bone

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

Step 7

Step 8

Bone

Lance drill

Drill 2.0/2.4

Drill 2.4/2.8

Drill 2.8/3.3

Drill 3.3/3.8

Drill 3.8/4.4

Countersink

Tap

Soft d4

Medium d3/d2

Hard d1

Sink countersink: up to 1.4mm for d3 medium bone/ up to 2.8mm for d2 medium bone and d1 compact bone
Use 4.1 countersink and 4.1 tap
For S1T implant system use the removal tool for abutments TRT after the implant has been placed in the bone

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

Step 7

Step 8

Bone

Lance drill

Drill 2.0/2.4

Drill 2.4/2.8

Drill 2.8/3.3

Drill 3.3/3.8

Drill 3.8/4.4

Countersink

Tap

Soft d4

Medium d3/d2

Hard d1

Sink countersink: up to 1.4mm for d3 medium bone/ up to 2.8mm for d2 medium bone and d1 compact bone
Use 4.7 countersink and 4.7 tap
For S1T implant system use the removal tool for abutments TRT after the implant has been placed in the bone

Step 1

Step 2

Step 3

Step 4

Step 5

Step 6

Step 7

Step 8

Bone

Lance drill

Drill 2.0/2.4

Drill 2.4/2.8

Drill 2.8/3.3

Drill 3.3/3.8

Drill 3.8/4.4

Countersink

Tap

Soft d4

Medium d3/d2

Hard d1

Download our surgical protocol

Login

Please insert user and password

X